Fire alarm control panel
Purpose: Remote display/control unit that mirrors the main fire alarm panel Use: Security rooms, entrances, multi‑floor buildings Display: Large graphical LCD for alarms and faults Loops: Supports up to 2 addressable loops (250 devices each) Outputs: 2 sounder lines + 3 programmable relays Inputs: 3 programmable dry contacts Memory: Event log up to 4000 records Voltage: 24V DC auxiliary output Communication: HST protocol, compatible with HST main panels Certifications: ISO 9001, CE Note: Not standalone – must connect to a main HST fire alarm panel
Manual Call Point – HST
Function: Manual fire alarm trigger – activates system when pressed Operation: Push in → pull down → alarm signal sent to control panel Design: Red ABS plastic, labeled “FIRE”, with reset key slot Mounting: Surface or flush mount Connection: Addressable or conventional (depends on system type) Compatibility: Works with HST fire alarm panels Certifications: ISO 9001, CE Use: Entrances, corridors, emergency exits, public areas Note: Must be installed at accessible height (typically 1.4m from floor)
Smoke & Heat Detector – HST
Function: Detects fire early via smoke or temperature rise Types: Smoke Detector – optical/photoelectric sensing Heat Detector – fixed temperature or rate-of-rise Application: Fire alarm systems in residential, commercial, and industrial buildings Mounting: Ceiling-mounted, standard base or addressable socket Connection: Conventional or addressable (HST protocol) Certifications: ISO 9001, CE, EN54 Voltage: Typically 24V DC Alarm Output: LED indicator + signal to control panel Use Zones: Corridors, rooms, technical areas, HVAC ducts Note
Fire Alarm Siren – HST
Function: Audible alert device that sounds during fire alarm activation Types: Electronic Siren – continuous or pulsing tone Mechanical Bell – traditional ringing sound Sound Level: Typically 90–110 dB at 1 meter Voltage: 24V DC (standard for fire systems) Mounting: Wall or ceiling surface mount Material: ABS plastic or metal casing (red color) Connection: Conventional or addressable output Certifications: ISO 9001, CE, EN54 Use Zones: Corridors, staircases, entrances, technical rooms Note: Must be installed per NFPA/EN54 spacing and audibility rules
Siren And Flasher – HST
Function: Combined audible and visual alert during fire alarm activation Sound Level: 90–110 dB at 1 meter Light Type: High-intensity LED strobe (red or white flash) Voltage: 24V DC (standard for fire systems) Mounting: Wall or ceiling surface mount Material: ABS plastic or metal casing (red color) Connection: Conventional or addressable output Certifications: ISO 9001, CE, EN54 Use Zones: Corridors, staircases, entrances, technical rooms Note: Must follow NFPA/EN54 spacing and visibility rules